Showing all 3 results

  • Explosion Proof Split Air Conditioner  BKT-3.5

    Explosion Proof Split Air Conditioner BKT-3.5

    0 out of 5

    Model: BKT-3.5 Explosion It’s made for use in classified hazardous zones such as Zone 1 and Zone 2 where explosive gas atmospheres may occur.
    Certification,for GB3836/ATEX/IECEx compliance
    Cooling capacity, 3500 W 12,000 BTU
    Heating capacity 4300 W
    Refrigerant: R410A 1.05 kg
    Cooling input power 750 W
    Heating input power 1274 W
    Works with 220 V/50 Hz, 208 V/60 Hz, or 110 V/60 Hz
    •range 7 °C to +52 c
    Airflow 550 m³/h

  • Explosion Proof Split Air Conditioner Model BKT 5.0Explosion Proof Split Air Conditioner[BKT-7.2F]

    Explosion Proof Split Air Conditioner Model BKT 5.0

    4.00 out of 5

    Model: BKT-5.0 Explosion Proof Split Air Conditioner
    Designed for hazardous classified as Zone 1 & Zone 2, safety standards like GB3836.1, suitable for gas groups IIA/IIB/IIC and temperature classes T1–T4.
    Cooling Capacity 5000W 17,000 BTU/h
    Heating Capacity 5500W
    Cooling Input Power 1400W
    Heating Input Power 1600W
    Refrigerant R410A 1.5 kg
    Air Flow Volume 910 m³/h
    Operating Ambient Temp 7°C to +52°C
    Indoor Unit Size (L×W×H) 910L× 320W× 230H mm
    Outdoor Unit Size 760 × 520 × 255 mm
    Weight 15 kg
    supplies: 220 V/50 Hz, 208 V/60 Hz, and 110 V/60 Hz.

  • Explosion Proof Split Air Conditioner Model BKT-7.2FExplosion Proof Split Air Conditioner[BKT-7.2F]

    Explosion Proof Split Air Conditioner Model BKT-7.2F

    5.00 out of 5

    Model BKT-7.2F Explosion Proof Split Air Conditioner
    Cooling Capacity 7,200 W 24,500 BTU/h
    Heating Capacity 8,400 W
    Cooling Input Power 2,600W
    Heating Input Power 2,750W
    Refrigerant R410A 1.8 kg
    Power Supply 220 V/50 Hz, 208 V/60 Hz, or 110 V/60 Hz
    Airflow Volume 1,050 m³/h
    Operating Temp Range approx. 7 °C to +52 °C
    Indoor Unit Size (mm) 1080 × 330 × 225
    Outdoor Unit Size (mm) 968 × 695 × 330
    Indoor Unit Weight 25 kg
    Outdoor Unit Weight 75 kg
    It meets hazardous location standards suitable for gas groups IIA, IIB, and IIC, and temperature class T4.

End of content

End of content

We denounce with righteous indignation and dislike men who are so beguiled and demoralized by the charms of pleasure of the moment, so blinded by desire, that they cannot foresee the pain and trouble that are bound to ensue; and equal blame belongs to those who fail in their duty through weakness of will, which is the same as saying through shrinking from toil and pain. These cases are perfectly simple and easy to distinguish. In a free hour.